Reusable silicone bag shaped to the mold, for series production. Cuts consumable use on lines where the same part repeats.

VT-S230
Operating range
≤ 230 °C · 7 bar≤ 446 °F · 102 psi
Thickness
1.5mm0.059in
Hardness
40Shore A
Elongation at break
600%
Sheet
1200 × 10,000mm47.2 × 393.7in
On request listTechnical data sheet

Technical properties

ParameterValueConditionTest method
Mechanical
Elongation at break — MD600%direction not stated
Hardness40Shore AISO 7619
Physical / dimensional
Thickness1.5mm0.059in
Sheet size1200 × 10,000mm47.2 × 393.7inopened sheet
Chemical / surface
Resin system compatibilityEpoxy, Polyester, Vinyl ester
Process / commercial
Process compatibilityOven cure, Vacuum infusion, Autoclave

Where it sits in the vacuum bag

The vacuum bag from mould to bag, with the layers each method uses. Hover over a layer or pick one from the list.

Method
7Vacuum bagThis productSeals the stack; under vacuum it presses atmospheric pressure onto the part.

Layers, top to bottom

Numbers show the layup order.

  1. 7Vacuum bagThis product
  2. 5Breather
  3. 4Release film
  4. 3Peel ply
  5. 2Laminate
  6. 6Sealant tape
  7. 1Mould

Representative layup; layers vary with the method and the part.

Operating range

≤ 230 °C · 7 bar≤ 446 °F · 102 psi
032100212200392300 °C572 °F
Maximum service temperature
230°C446°F
Pressure resistance
7bar102psi

Method suitability

  • Oven cureSuitableSuitable for Oven cure

    Reusable; made for the specific mold, so the first setup takes time.

  • Vacuum infusionSuitableSuitable for Vacuum infusion

    Cuts bagging time in series production.

  • AutoclaveSuitableSuitable for Autoclave

    Fast for repeat parts; made for the specific mold, so tedious for a single part.

Supply and storage

Resin compatibility
  • Epoxy
  • Polyester
  • Vinyl ester
Packaging
Sheet on a roll
Storage
At room temperature, without folding

Alternatives in this group

Vacuum Bag Film · Differences are relative to this product.

CompareProductT max °C°FP max barpsiElongation at breakThicknessTensile strength at breakOvenInfusionAutoclaveProduct page
Co-extruded Vacuum Bagging FilmVT-P120120°C248°F−110−198–500%−100−10075–80µm2.95–3.15mil–Not used with this methodSuitable for Vacuum infusionNot used with this method
Self-Releasing Vacuum Bagging FilmVT-K150B150°C302°F−80−144–500%−100−10050µm1.97mil50MPaSuitable for Oven cureSuitable for Vacuum infusionSuitable for Autoclave
Co-extruded Vacuum Bagging Film, Epoxy and PhenolicVT-K170170°C338°F−60−108–400%−200−20050µm1.97mil45MPaSuitable for Oven cureSuitable for Vacuum infusionSuitable for Autoclave
Modified Nylon Vacuum Bagging FilmVT-N204B204°C399°F−26−476.9bar100psi−0.1−1415%−185−18550µm1.97mil96MPaSuitable for Oven cureSuitable for Vacuum infusionSuitable for Autoclave
Nylon Vacuum Bagging FilmVT-N200212°C414°F−18−32–550%−50−5050µm1.97mil95MPaSuitable for Oven cureSuitable for Vacuum infusionSuitable for Autoclave
Silicone Vacuum Membranethis productVT-S230230°C446°F7bar102psi600%1.5mm0.059in–Suitable for Oven cureSuitable for Vacuum infusionSuitable for Autoclave
Modified Nylon Vacuum Bagging Film, 232 °CVT-N232232°C450°F+2+46.9bar100psi−0.1−1350%−250−25050µm1.97mil85MPaSuitable for Oven cureSuitable for Vacuum infusionSuitable for Autoclave